V2000-c Rfid Access Control User Manual Jun 2026
Re-enter the to confirm, followed by # . Press ** to save and exit programming. User Card / Key Fob Registration
| J1 Jumper Position | COM (J3) Connection | PUSH1 & COM State | Use Case | | :--- | :--- | :--- | :--- | | | GND | Normally Open | Fail-secure electric strike | | NC | GND | Normally Closed | Fail-safe magnetic lock | | NO | 12V | Normally Open (Outputs 12V) | Directly powering a low-current device | | NC | 12V | Normally Closed (Outputs 12V) | Directly powering a low-current device | | NO | Not Connected | Normally Open (Dry Contact) | General relay use | | NC | Not Connected | Normally Closed (Dry Contact) | General relay use | V2000-c Rfid Access Control User Manual
All user data (cards, PIN codes, system settings) is stored in non-volatile memory. The device retains all information during power outages without requiring a backup battery. Re-enter the to confirm, followed by #
Use the rear plate of the enclosure as a template to mark drill locations for the wall anchors. The device retains all information during power outages
Normally Closed relay contact (used for fail-safe magnetic locks)
In programming mode, press 1 + Slot ID (e.g., 001 to 999) + # + Swipe Card + # .