| Source Type | Source Name / Link | Notes | | --- | --- | --- | | | 天津沐恒称重设备科技有限公司 (Tianjin Muheng Weighing Equipment) | This page contains a direct link to download the PDF manual. | | Distributor | 上海仪展衡器有限公司 (Shanghai Yizhan Scale) | The page provides a full manual in PNG format. | | Product Page | 广州市怡华新电子仪器有限公司 (Guangzhou Yihuaxin) | A product page with a "download attachment" link that may provide the manual. | | Technical Article | b2bwiki.baidu.com article | This page provides a detailed breakdown of parameter settings and calibration. | | Calibration Guide | chem17.com calibration page | An excellent resource for the specific calibration procedure. |
Shanghai Yaohua (often branded as "Kingbird" or "Keli") maintains an archive of older manuals. Due to frequent domain changes, the current best practice is:
You do not need to pay for this document. The manufacturer distributes it freely.
| Parameter | Specification | | --- | --- | | | 80 times / second | | A/D Resolution | 1/30000 | | Nonlinearity | ≤0.01% F.S. | | Sensor Excitation | 5V DC, 200mA | | Sensor Connection | 1-4 x 350Ω load cells (6-wire, with long-line compensation) | | Display | 6-digit, 0.3-inch high LED | | Enclosure / Mounting | DIN-rail mounting (77mm x 132mm x 58mm) | | Power Supply | DC 12~30V | | Operating Temp. | 0℃~40℃ |
Calibration is the most critical procedure to ensure accuracy. While the C801 supports a "no-weight" calibration using sensor parameters, a standard calibration with test weights is the most reliable method. Here’s the general process: xk3190c801 manual free
) with a 6-wire system for automatic long-line compensation. Interface Options
Exiting the menu and saving the new parameters.
Do you need the for PLC communication?
Complete User Guide: XK3190-C801 Weighing Indicator Manual The XK3190-C801 weighing indicator is a high-performance, industrial-grade weighing controller. It is widely used in batching scales, filling machines, and tensile testing systems. This comprehensive guide serves as your free digital manual, covering technical specifications, wiring configurations, calibration procedures, and troubleshooting steps. Technical Specifications | Source Type | Source Name / Link
Complete Guide to the XK3190-C801 Weighing Indicator: Setup, Calibration, and Manual Download
In this article, we provide a direct guide to accessing your legally, along with a condensed "cheat sheet" of the most critical functions you need to operate your scale today.
Set the decimal point position [ P X ] (e.g., 0, 0.0, 0.00). Press . Step 3: Set Maximum Capacity The screen will display [ FULL ] .
The XK3190-C8 series is designed for robust industrial applications. It is not just an indicator but a full controller. | | Technical Article | b2bwiki
Calibration requires a certified test weight. Ensure the scale base is level and free from mechanical binding before beginning. Step 1: Enter Calibration Mode Power off the indicator.
If you are waiting to download your full manual, here is the cheat sheet:
: Rated at Level 3 accuracy with high-speed A/D conversion capable of up to 80 samples per second. Operations and Manual Content
Check load cell wiring; ensure load cells are not mechanically jammed. Zero calibration out of range